50 research outputs found

    Application of P300 Event-Related Potential in Brain-Computer Interface

    Get PDF
    The primary purpose of this chapter is to demonstrate one of the applications of P300 event-related potential (ERP), i.e., brain-computer interface (BCI). Researchers and students will find the chapter appealing with a preliminary description of P300 ERP. This chapter also appreciates the importance and advantages of noninvasive ERP technique. In noninvasive BCI, the P300 ERPs are extracted from brain electrical activities [electroencephalogram (EEG)] as a signature of the underlying electrophysiological mechanism of brain responses to the external or internal changes and events. As the chapter proceeds, topics are covered on more relevant scholarly works about challenges and new directions in P300 BCI. Along with these, articles with the references on the advancement of this technique will be presented to ensure that the scholarly reviews are accessible to people who are new to this field. To enhance fundamental understanding, stimulation as well as signal processing methods will be discussed from some novel works with a comparison of the associated results. This chapter will meet the need for a concise and practical description of basic, as well as advanced P300 ERP techniques, which is suitable for a broad range of researchers extending from today’s novice to an experienced cognitive researcher

    A Fuzzy Logic System for Seizure Onset Detection in Intracranial EEG

    Get PDF
    We present a multistage fuzzy rule-based algorithm for epileptic seizure onset detection. Amplitude, frequency, and entropy-based features were extracted from intracranial electroencephalogram (iEEG) recordings and considered as the inputs for a fuzzy system. These features extracted from multichannel iEEG signals were combined using fuzzy algorithms both in feature domain and in spatial domain. Fuzzy rules were derived based on experts' knowledge and reasoning. An adaptive fuzzy subsystem was used for combining characteristics features extracted from iEEG. For the spatial combination, three channels from epileptogenic zone and one from remote zone were considered into another fuzzy subsystem. Finally, a threshold procedure was applied to the fuzzy output derived from the final fuzzy subsystem. The method was evaluated on iEEG datasets selected from Freiburg Seizure Prediction EEG (FSPEEG) database. A total of 112.45 hours of intracranial EEG recordings was selected from 20 patients having 56 seizures was used for the system performance evaluation. The overall sensitivity of 95.8% with false detection rate of 0.26 per hour and average detection latency of 15.8 seconds was achieved

    Hybrid Brain-Computer Interface Systems: Approaches, Features, and Trends

    Get PDF
    Brain-computer interface (BCI) is an emerging field, and an increasing number of BCI research projects are being carried globally to interface computer with human using EEG for useful operations in both healthy and locked persons. Although several methods have been used to enhance the BCI performance in terms of signal processing, noise reduction, accuracy, information transfer rate, and user acceptability, the effective BCI system is still in the verge of development. So far, various modifications on single BCI systems as well as hybrid are done and the hybrid BCIs have shown increased but insufficient performance. Therefore, more efficient hybrid BCI models are still under the investigation by different research groups. In this review chapter, single BCI systems are briefly discussed and more detail discussions on hybrid BCIs, their modifications, operations, and performances with comparisons in terms of signal processing approaches, applications, limitations, and future scopes are presented

    Biomedical Signal Transceivers

    Get PDF
    With the growing costs of healthcare, the need for mobile health monitoring devices is critical. A wireless transceiver provides a cost effective way to transmit biomedical signals to the various personal electronic devices, such as computers, cellular devices, and other mobile devices. Different kinds of biomedical signals can be processed and transmitted by these devices, including electroencephalograph (EEG), electrocardiograph (ECG), and electromyography (EMG). By utilizing wireless transmission, the user gains freedom to connect with fewer constraints to their personal devices to view and monitor their health condition. In this chapter, in the first few sections, we will introduce the reader with the basic design of the biomedical transceivers and some of the design issues. In the subsequent sections, we will be presenting design challenges for wireless transceivers, specially using a common wireless protocol Bluetooth. Furthermore, we will share our experience of implementing a biomedical transceiver for ECG signals and processing them. We conclude the discussion with current trends and future work

    Pain Identification in Electroencephalography Signal Using Fuzzy Inference System

    Get PDF
    Diagnosing pain mechanisms is one of main approaches to improve clinical treatments. Especially, detection of existence and/or level of pain could be vital when oral information is not present for instant for neonates, disabled persons, anesthetized patients and animals. Various researches have been performed to originate and classify the pain; however, consistent results are surprising. The aim of this study is to show a strict relation between electroencephalography (EEG) features and perceptual pain levels and to clarify the relation of classified signal to pain origin. Cortical regions on scalp are assigned based on an evolutional method for optimized alignment of electrodes that improve the clinical monitoring results. The EEG signals are recorded during relax condition and variety of pain conditions. Evolutionary optimization method is used to reduce the features space dimension and computational costs. A hybrid adaptive network fuzzy inference system (ANFIS) and support vector machine (SVM) scheme is used for classification of pain levels. ANFIS optimizer is used to fine tune the non-linear alignment of kernels of SVM. The results show that pain levels could be differentiated with high accuracy and robustness even for few recording electrodes. The proposed classification method provides up to 95% accuracy

    Vertical Ground Reaction Force Marker for Parkinson’s Disease

    Get PDF
    Parkinson’s disease (PD) patients regularly exhibit abnormal gait patterns. Automated differentiation of abnormal gait from normal gait can serve as a potential tool for early diagnosis as well as monitoring the effect of PD treatment. The aim of current study is to differentiate PD patients from healthy controls, on the basis of features derived from plantar vertical ground reaction force (VGRF) data during walking at normal pace. The current work presents a comprehensive study highlighting the efficacy of different machine learning classifiers towards devising an accurate prediction system. Selection of meaningful feature based on sequential forward feature selection, the swing time, stride time variability, and center of pressure features facilitated successful classification of control and PD gaits. Support Vector Machine (SVM), K-nearest neighbor (KNN), random forest, and decision trees classifiers were used to build the prediction model. We found that SVM with cubic kernel outperformed other classifiers with an accuracy of 93.6%, the sensitivity of 93.1%, and specificity of 94.1%. In comparison to other studies, utilizing same dataset, our designed prediction system improved the classification performance by approximately 10%. The results of the current study underscore the ability of the VGRF data obtained non-invasively from wearable devices, in combination with a SVM classifier trained on meticulously selected features, as a tool for diagnosis of PD and monitoring effectiveness of therapy post pathology
    corecore